Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches 762 mm or greater over an area of not less than 30 square feet 2 8 m 2.
Irc required attic access.
Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that exceed 30 square feet 2 8 m 2 and have a vertical height of 30 inches.
The 2009 and 2015 irc verbiage is similar and still applicable.
Wednesday july 4 2018.
The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members.
2012 iecc irc stair code review pdf of attic access requirements includes discussion of compliance with the 2012 iecc energy code for insulation and air sealing for attics for conditioned and unconditioned space separation.
Habitable attics require a vertical access and emergency escape and rescue opening.
The 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
From section r807 in the 06 irc.
Chapter 10 city amendment.
This is applicable to finished and unfinished spaces.
The rough framed opening.
Attic area exceeds 30 square feet and.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
Iecc versions prior to 2009 did not specify details for attic access hatches and doors.
Minimum vertical height of 30 inches measured from the top of the ceiling framing members to the bottom of the roof framing members.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.